FloMOD Sizing Tool

Welcome — Design Your FloMOD System

Input System Requirements

Input Design Parameters

FloMOD-m16V

Cells per Module [Na] 6
Cell Rated Voltage (V) [Vc] 2.85
Cell BOL Capacitance (F) [Ca] 3000
Cell BOL ESR (mOhm) [Ra] 0.20
Module Additional ESR (mOhm) [Rb] 1

System Configuration

Max Design/De-Rated Voltage (V) [Vk] -
System EOL ESR (mOhm) [Rh] -
System EOL Capacitance (F) [Ch] -
Modules in Series per Branch [Nb] -
System EOL Duration (s) [Tc] -
Branch Voltage (V) at the end of Ta Sec [Vl] -
Parallel Branches per System [Nf] -

FloMOD-m32V

Cells per Module [Na] 12
Cell Rated Voltage (V) [Vc] 2.85
Cell BOL Capacitance (F) [Ca] 3000
Cell BOL ESR (mOhm) [Ra] 0.20
Module Additional ESR (mOhm) [Rb] 1

System Configuration

Max Design/De-Rated Voltage (V) [Vk] -
System EOL ESR (mOhm) [Rh] -
System EOL Capacitance (F) [Ch] -
Modules in Series per Branch [Nb] -
System EOL Duration (s) [Tc] -
Branch Voltage (V) at the end of Ta Sec [Vl] -
Parallel Branches per System [Nf] -

FloMOD-m48V

Cells per Module [Na] 18
Cell Rated Voltage (V) [Vc] 2.85
Cell BOL Capacitance (F) [Ca] 3000
Cell BOL ESR (mOhm) [Ra] 0.20
Module Additional ESR (mOhm) [Rb] 1

System Configuration

Max Design/De-Rated Voltage (V) [Vk] -
System EOL ESR (mOhm) [Rh] -
System EOL Capacitance (F) [Ch] -
Modules in Series per Branch [Nb] -
System EOL Duration (s) [Tc] -
Branch Voltage (V) at the end of Ta Sec [Vl] -
Parallel Branches per System [Nf] -

FloMOD-m64V

Cells per Module [Na] 24
Cell Rated Voltage (V) [Vc] 2.85
Cell BOL Capacitance (F) [Ca] 3000
Cell BOL ESR (mOhm) [Ra] 0.20
Module Additional ESR (mOhm) [Rb] 1

System Configuration

Max Design/De-Rated Voltage (V) [Vk] -
System EOL ESR (mOhm) [Rh] -
System EOL Capacitance (F) [Ch] -
Modules in Series per Branch [Nb] -
System EOL Duration (s) [Tc] -
Branch Voltage (V) at the end of Ta Sec [Vl] -
Parallel Branches per System [Nf] -

FloMOD-m80V

Cells per Module [Na] 30
Cell Rated Voltage (V) [Vc] 2.85
Cell BOL Capacitance (F) [Ca] 3000
Cell BOL ESR (mOhm) [Ra] 0.20
Module Additional ESR (mOhm) [Rb] 1

System Configuration

Max Design/De-Rated Voltage (V) [Vk] -
System EOL ESR (mOhm) [Rh] -
System EOL Capacitance (F) [Ch] -
Modules in Series per Branch [Nb] -
System EOL Duration (s) [Tc] -
Branch Voltage (V) at the end of Ta Sec [Vl] -
Parallel Branches per System [Nf] -

FloMOD-m96V

Cells per Module [Na] 36
Cell Rated Voltage (V) [Vc] 2.85
Cell BOL Capacitance (F) [Ca] 3000
Cell BOL ESR (mOhm) [Ra] 0.20
Module Additional ESR (mOhm) [Rb] 1

System Configuration

Max Design/De-Rated Voltage (V) [Vk] -
System EOL ESR (mOhm) [Rh] -
System EOL Capacitance (F) [Ch] -
Modules in Series per Branch [Nb] -
System EOL Duration (s) [Tc] -
Branch Voltage (V) at the end of Ta Sec [Vl] -
Parallel Branches per System [Nf] -

FloMOD-Custom

System Configuration

Max Design/De-Rated Voltage (V) [Vk] -
System EOL ESR (mOhm) [Rh] -
System EOL Capacitance (F) [Ch] -
Modules in Series per Branch [Nb] -
System EOL Duration (s) [Tc] -
Branch Voltage (V) at the end of Ta Sec [Vl] -
Parallel Branches per System [Nf] -